А.А. Sarukhanyan (baljyan-1951@list.ru), Р.Н. Baljyan (baljyan-1951@list.ru)

Abstract

To assess the technical condition of Azat Reservoir, observations, measurements, and discussions with operational personnel were conducted. The study included an examination of filtration conditions through the body of the earthen dam, an evaluation of the operational status of the irrigation water discharge and emergency drainage, and an assessment of the functionality of mechanical devices. Based on the analysis of the research results, key measures have been proposed. Implementation of these measures is expected to significantly enhance the operational safety and efficiency of Azat Reservoir and reduce possible emergency risks.

Keywords: reservoir, earthen dam, drainage structure, filtration, mechanical equipment, technical condition assessment.

PAGES: 89-95

DOI: 10.61746/18292984-2023.2-89

PDF